Technical Service Bulletin Phone: 814-238-2700 TSB # 60
GENERAL DYNAMICS, State College, PA Fax: 814-238-6243 Per ECR # 11428
Product(s) affected:
Outdoor and Antenna Mount SSPAs
Description of problem:
12245 Serial I/O Protocol has errors or misleading descriptions in messages 16.55 & 16.5A.
Design change to resolve problem:
Updated 12245 Serial I/O Protocol to Rev I.
Instructions for modification:
Use revised document, see attached.
Units that must be modified:
None.
Units that do not need to be modified:
Cognizant Engineer: Date:
Peter Trippett
8/15/2012
7364 Form 4 11/6/2001
Vedere la pagina 0
1 2 3 4 5 6 ... 40 41

Sommario

Pagina 1

Technical Service Bulletin Phone: 814-238-2700 TSB # 60GENERAL DYNAMICS, State College, PA Fax: 814-238-6243 Per ECR # 11428Product(s) affected:Outdoo

Pagina 2 - State College, PA 16801

Document 12245 Rev. I Sheet 9 of 39 If further data is included, if follows the instruction code and is referred to as the message body. Some instr

Pagina 3

Sheet 10 of 39 Document 12245 Rev. I Where more than one data value is sent, they are usually separated by some delimiter such as a comma (“,” ASCI

Pagina 4

Document 12245 Rev. I Sheet 11 of 39 01 blb5 0 blb3blb2 1 blb0 lbx will be a label that identifies the function of each bit 0 represents bits that

Pagina 5

Sheet 12 of 39 Document 12245 Rev. I EXAMPLE: An enumerated control currently has settings for “OFF” (30) and “ON” (31). In the future, a third cho

Pagina 6 - 1 Message Framing Format

Document 12245 Rev. I Sheet 13 of 39 This protocol was designed to be somewhat compatible with that of earlier SSPA products. Some messages that ar

Pagina 7 - 1.7.1 Rejected Messages

Sheet 14 of 39 Document 12245 Rev. I Message Table Instr Sub-Instr Name/(Section) Data Values  Sent to Amplifier  Returned by Amplifier

Pagina 8 - 1.8.2 Inter-message spacing

Document 12245 Rev. I Sheet 15 of 39 Message Table Instr Sub-Instr Name/(Section) Data Values  Sent to Amplifier  Returned by Amplifier

Pagina 9 - 2 Messages

Sheet 16 of 39 Document 12245 Rev. I Message Table Instr Sub-Instr Name/(Section) Data Values  Sent to Amplifier  Returned by Amplifier

Pagina 10 - 2.2 Data Values

Document 12245 Rev. I Sheet 17 of 39 Message Table Instr Sub-Instr Name/(Section) Data Values  Sent to Amplifier  Returned by Amplifier

Pagina 11 - 2.2.3 Bit Flag Value

Sheet 18 of 39 Document 12245 Rev. I Message Table Instr Sub-Instr Name/(Section) Data Values  Sent to Amplifier  Returned by Amplifier

Pagina 12 - 2.2.5 Protocol Symbols

CONTRACT NO. DRAWN BY DATE 60 Decibel Road, Suite 200 State College, PA 16801 Paul E. Phillips 5/31/00 TITLE CHECKED BY Serial I/O Prot

Pagina 13 - 2.5 Message Table

Document 12245 Rev. I Sheet 19 of 39 Message Table Instr Sub-Instr Name/(Section) Data Values  Sent to Amplifier  Returned by Amplifier

Pagina 14

Sheet 20 of 39 Document 12245 Rev. I 3 Message Details 3.1 Reset Microprocessor (04) This command forces a power-up reset of the microprocessor in

Pagina 15

Document 12245 Rev. I Sheet 21 of 39 bxSUM_VOLTAGE The Power Supply Voltage fault in older amplifiers. This flag is set if the module’s input volt

Pagina 16

Sheet 22 of 39 Document 12245 Rev. I 01 00 bAFLT_ANT_DL_FAIL bAFLT_RC_FAILURE bAFLT_FAN2_WARN bAFLT_FAN1_WARN bxFLT_EXT_INH One or more signals th

Pagina 17

Document 12245 Rev. I Sheet 23 of 39 3.4 Clear Service Request (09) This command clears a service request, and causes the service request contacts

Pagina 18 - (3.9.10)

Sheet 24 of 39 Document 12245 Rev. I 3.8.1 Get Output Power (16 50) The SSPA’s output power level will be returned as an analog value. The value w

Pagina 19

Document 12245 Rev. I Sheet 25 of 39 bMUTED:SERIO Muted by Serial I/O bMUTED:LOCAL Muted by local MUTE button (or on power-up if power-up state

Pagina 20

Sheet 26 of 39 Document 12245 Rev. I The following table lists the codes that are returned in response to the 16 59 message. They represent every f

Pagina 21 - 3 Message Details

Document 12245 Rev. I Sheet 27 of 39 Fault Codes SIO Code (16 59) Screen Text 1 (RCP-200X) SIO 08 flag 2 NEW_INFO SIO 08 flag 2 (old style) Descri

Pagina 22 - 3.3.2 “New” Fault Mask

Sheet 28 of 39 Document 12245 Rev. I 3.8.10 Get Configuration (16 5A) This message returns information about the SSPA hardware. The following info

Pagina 23

(Intentionally blank page.)

Pagina 24 - 3.7 Local Lockout (0E)

Document 12245 Rev. I Sheet 29 of 39 There is also a Reflected Power Calibration offset setting (see 3.9.10), which the operator may use to adjust

Pagina 25

Sheet 30 of 39 Document 12245 Rev. I 3.8.15 Get Module Nominal Power (16 6A) The Get Module Nominal Power command returns the rated nominal power

Pagina 26

Document 12245 Rev. I Sheet 31 of 39 To set the power limits, you need only send the values you wish to change. If you wish to affect only the uppe

Pagina 27 - ACTIVE_INFO

Sheet 32 of 39 Document 12245 Rev. I 3.9.7 Power-Up State (17 58) The Power Up State setting determines whether, when powered-up, a unit should be

Pagina 28

Document 12245 Rev. I Sheet 33 of 39 When queried or set, a signed analog value is passed in this message. This value is the offset (in dB) to get

Pagina 29

Sheet 34 of 39 Document 12245 Rev. I If you turn on Remote Disables Local while the amplifier is in Remote Mode, you will immediately lose the abil

Pagina 30

Document 12245 Rev. I Sheet 35 of 39 Units will respond with a message containing the same instruction code and sub-instruction, and a message body

Pagina 31 - 3.9 Configuration (17)

Sheet 36 of 39 Document 12245 Rev. I Example, set PIO output R5 to the Normally Open position and R6 to the Normally Closed position (assuming neit

Pagina 32

Document 12245 Rev. I Sheet 37 of 39 3.11.2 AntDL Switch Command (19 54) This command message accepts only one one-byte parameter, which is: 30:

Pagina 33

Sheet 38 of 39 Document 12245 Rev. I bCONTROL_MODE_LOCAL_OR_MAINTENANCE = Control Mode is set to Local or Maintenance. bCONTROL_MODE_REMOTE_OR_MA

Pagina 34 - REMOTE_DISABLES_LOCAL_SETTING

Document 12245 Rev. I Sheet 3 of 39 Table of Contents 1 Message Framing Format...

Pagina 35

Document 12245 Rev. I Sheet 39 of 39 After the fault condition has been rectified, bits can be cleared in the Latched Fault Mask by issuing a Fault

Pagina 37 - 3.11 Commands (19)

Sheet 4 of 39 Document 12245 Rev. I 3.8.4 Get Input Voltage (16 53)...

Pagina 38 - 3.13 Unit Status (20)

Document 12245 Rev. I Sheet 5 of 39 Serial I/O comes as a standard feature. By sending and receiving commands over an RS-232, RS-485 (2-wire), RS-4

Pagina 39 - 4 Faults and Alarms

Sheet 6 of 39 Document 12245 Rev. I 1.5 Message Data The actual content of the message starts with the least significant 6 bits of Byte 4, and can

Pagina 40 - 4.2 Fault Descriptions

Document 12245 Rev. I Sheet 7 of 39 A message may also be rejected at a higher level, if something is wrong with the MESSAGE DATA itself (e.g. ille

Pagina 41

Sheet 8 of 39 Document 12245 Rev. I If an ACK response is requested on every message, the host will know if a message was rejected (for any reason)